Oxygen permeation analyzer

NegotiableUpdate on 05/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
OX-TRAN 2/28 H is designed for laboratories that typically require extensive OTR testing of medium to high barrier materials. $r $n $r $n Oxygen Permeation Analyzer $r $n Testing Membrane $r $nASTM D3985 $r $n4 Chamber Test Cabin System
Product Details

OX-TRAN 2/28 H, due to its unique 4-test chamber, can simultaneously test 4 barrier samples, with a throughput twice that of traditional OTR instruments. The new dual membrane horizontal testing chamber can be disassembled for sample preparation, and the user-friendly interface provides real-time comparison of testing status and target limits.

highest precision

  • Coulox ® The sensor is an absolute coulomb meter sensor on the market that does not require calibration

  • The detection limit is as low as 0.05 cc/(m2* day)

  • Fully automatic temperature and flow control simplifies testing and provides repeatability

High throughput

  • The industry's fastest sensor response time reduces overall testing time

  • The double membrane detachable test chamber allows for testing 4 samples at once, requiring less space

  • Automatic testing method, one click start testing

  • TruSeal nitrogen circulation seal can eliminate the need for absolute zero point in many tests, thereby reducing overall testing time

The OX-TRAN 2/28 H high-throughput analyzer can test the oxygen permeability (OTR) of high and low barrier membranes without the need for humidification. It uses MOCON's Coulox absolute value Coulombometer sensor, which does not require calibration and complies with ASTM D3985 standard. The analyzer ranges from 0.05 to 200 cc/(m2*The wide detection range of day provides very accurate and reproducible test results.

The 4 test chambers allow for the use or non use of reference films for testing in triplicate within the same test. Choosing to run known standard samples as controls can improve the credibility of the results. OX-TRAN 2/28 H has 4 test chambers, which are easy to operate and very suitable for quality control laboratories that perform a large number of OTR tests.

This analyzer has industry features such as a detachable horizontal testing chamber, fully automated testing, and can provide higher throughput in the laboratory. It also has a QC testing mode that can display real-time comparisons between test status and target limits. It can be equipped with a touch screen operation interface, and versions without a touch screen operation interface can be controlled through the local computer's color graphical interface.

For over 25 years, the MOCON OX-TRAN series instruments have been reliable and durable in the market. OX-TRAN 2/28 H is an excellent choice for conducting routine short penetration tests in busy laboratories.


Characteristics and advantages

Detachable test chamber
  • Double membrane testing chamber box, doubling testing capability

  • Easily prepare samples on the workbench

  • One click release and loading

  • Pneumatic clamping ensures more reproducible results

  • Additional test chambers can be loaded and tested in stages

TruSeal®
  • Eliminate individual zeroing

  • Shorten testing time (improve throughput)

  • More reproducible results

Automatic control function
  • Store and call commonly used testing methods

  • One click start of complete testing cycle

  • Perform flow and temperature control throughout the entire testing cycle

  • Preprocessing mode to improve throughput

  • Printing and exporting test reports, including pass, fail, or warning test results

  • Sensor protection

Simple user interface
  • The full-color graphical interface displays the comparison between real-time detection status and target limits

  • The instrument can be equipped with a color touch screen or connected to a PC

  • Intuitive automation operations require minimal training

  • Built in multi-level user management and data security

  • Event logs and troubleshooting guidelines

Coulox ® sensor
  • Shorten testing time, reduce overall testing time, and improve throughput

  • No need for sensor calibration

  • The lifespan of the sensor is longer than other sensors on the market

  • Compared to sensors that require calibration, the results are more accurate and reproducible

  • The sensor complies with ASTM D3985

warranty
  • 12-month 100% parts and process warranty

  • Coulox Sensor 4-Year Warranty


Function - Specific Model

unit

OX-TRAN 2/28H

OX-TRAN 2/28HR

Test scope (50cm2)

cc/(m2*Oh my god)

0.05 to 200

0.05 to 200

cc/(100 in2*(Heaven)

0.003 to 12.9

0.003 to 12.9

Test scope (5)cm2)

cc/(m2*(Heaven)

0.5 to 2000

0.5 to 2000

cc/(100 in2*Oh my god)

0.03 to 129.0

0.03 to 129.0

Resolve (50cm)2)

cc/(m2*(Heaven)

0.0001

0.0001

repetitiveness

cc/(m2*(Heaven)

0.02 or 1%*

0.02 or 1%*

Test temperature range

°C

20 ° to 60 ° C ± 0.2 ° C

20 ° to 40 ° C ± 0.2 ° C

Controlled relative humidity testing range

%Relative humidity

0

0%, 50-90%+/-5%, only testing gases

Film Size

Not applicable

4” x 4” std., 2” x 2” for 5.0 cm2

4” x 4” std., 2” x 2” for 5.0 cm2

film thickness

Not applicable

Up to 20 Mil for 50 cm2. Up to 120 Mil for 5.0+10 cm2

Up to 20 Mil is 50 cm2, up to 120 Mil is 5.0+10 cm2

Thin film testing area

Not applicable

50 cm2 standard, 10 cm2+5.0 cm2 elective

50 cm2 standard, 10 cm2+5.0 cm2 elective

*Whichever is larger

Other specifications (all models):

Physical specifications

  • 15.5 inches high x 12 inches wide x 23 inches deep (39.4 cm x 30.4 cm x 58.0 cm)

  • 95 pounds (43.1 kg)

Electrical requirements

  • Voltage: 100-240 VAC 50/60 Hz

  • Maximum power consumption: 700 VA

Laboratory requirements

temperature

operation

22°C ± 2°C

storage

10 ° C to 30 ° C

humidity

operation

20% to 80% RH (non condensing)

storage

5% to 85% RH (non condensing)

Gas supply requirements

carrier gas

gas composition

Nitrogen/hydrogen mixture (98%/2%)

Rated gas supply pressure

25 PSI, (1.72 bar), (172 kPa)

Test gas

gas composition

100% oxygen (purity 99.9%)

Rated gas supply pressure

25 PSI, (1.72 bar), (172 kPa)

connect
  • Remote access and control (requires optional Perm Net Light software)

  • Standard Ethernet port (100T)

  • Dual USB 2.0 ports (for connecting keyboards, mice, or storage devices)

Compliance standards

This product is certified by UL and CSA, uses the ETL mark of Intertek Group plc, and has passed CE certification.

Meets the following safety standards.

  • IEC 61010-1:2010 Third Edition

  • UL 61010-1:2012 Third Edition

  • CAN/CSA-C22.2 No. 61010-1:2012 Third Edition

Meets the following EMC standards.

  • EN 61326-1:2013

  • EN 61000-3-2:2006、A1:2009、A2:2009

  • EN 61000-3-3:2013

Compliant with the EU RoHS Directive 2011/65/EU.


accessories


Test cabin and options
  • Additional double membrane testing cabin

consumables
  • Certification film 1-3

  • face shield

software
  • PermWare Data Collection, Data Management, and Instrument Status Dashboard

  • 21 CFR Part 11 User and Data Security

  • PC Remote Viewing Software - PermNet Lite

Service and Support Options
  • Basic Preventive Maintenance Plan

  • Advanced Preventive Maintenance Plan


application

packaging film

  • single layer

  • multi-layer

  • Coating film

Test Standard

ASTM D3985
ASTM F2622
ISO CD 15105-2
JIS K-7126-B
DIN 53380-3
GB/T 19789-2005

test method

According toASTM D3985

Standard test method for determining the transmittance of oxygen through plastic films and sheets using a coulomb sensor

Install the test sample as a semi barrier material between two chambers under ambient atmospheric pressure. One chamber is slowly purged with nitrogen gas flow, while the other chamber contains oxygen. When oxygen permeates through the membrane into the nitrogen carrier gas, it will be transported to the coulomb detector, where a current is generated that is proportional to the amount of oxygen entering the detector per unit time.