Oxygen permeation analyzer

NegotiableUpdate on 01/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
OX-TRAN 2/22 Series - Single Cell $r $nOX-TRAN 2/22 1-cell is MOCON's OTR analyzer designed specifically for small laboratories. $r $n $r $n Oxygen Permeation Analyzer $r $n Testing Film and Packaging $r $nASTM D3985 $r $n1 Unit Ink Cartridge System
Product Details

Oxygen permeation analyzer

OX-TRAN 2/22 Series - Single Battery

The OX-TRAN 2/22 series 1 unit high-performance analyzer can test the oxygen permeability (OTR) of films and packaging with low to moderate barrier properties. These low-cost analyzers for packaging and film are easy to use and provide short testing times on the market. They have a replaceable horizontal testing box that can easily and accurately test various sample sizes and types.

Z high accuracy

  • Obtained COUPOX®The sensor is an absolute Coulomb sensor on the market, which does not require calibration

  • Detection level as low as 0.05 cc/(m2X days (H model)

  • Fully automatic temperature, flow, and relative humidity control simplifies testing and provides repeatability

Easy to use

  • Fast sensor response time in the industry can shorten overall testing time

  • The detachable test box can easily prepare samples on the workbench

  • Automated testing method, just press a button to start testing

  • TruSeal®Gas flushing of the surrounding seal can reduce the background level, thereby obtaining more accurate test results

The 2/22 series uses MOCON's COUPOX absolute (intrinsic) coulombic sensor, which does not require calibration and is the basis of ASTM standardsD3985It is an instrument series that has been independently tested and proven to meet accuracy and bias requirements by a third party.

Model:
This series of high-precision instruments has two models with different detection limits.

  • model(Low barrier) - able to test common barriers, providing a range of 0.1 to 200 cc/(m)2X days)

  • H model(Medium Barrier) - The popular detection range is 0.05 to 200 cc/(m)2X days)

Its detection limit is 200 cc/(m2X days), can be used throughReduced area film test boxAtmospheric oxygen replaces normal 100% oxygen2(Coefficient 4.8) or masking of various sizes. This series has industry features such as detachable and interchangeable level test boxes, easy-to-use touchscreen operator interfaces, and fully automated testing that provides higher throughput in the laboratory.

For 25 years, MOCON's OX-TRAN series instruments have been trusted and durable in the market. From simple single-layer guardrails to complex multi-layer guardrails, the OX-TRAN 2/22 series is the right choice.


Characteristics and advantages

Removable ink cartridge
  • Easily prepare samples on the desktop

  • One click release and loading

  • Pneumatic clamping can provide more reproducible results

  • Interchangeable ink cartridge options can expand the range and flexibility of the analyzer without the need for tools, while maintaining curved results

  • The filter options include: reducing the area to expand the scope of mask free testing, improving the accuracy of paper barrier testing, adapters for remote testing of packaging or harsh conditions, and customized designs to meet unique testing requirements.

TruSeal®
  • Gas flushing of sample installation seals can protect the integrity of the chamber

  • Reduce background level and minimize the need for individual zeroing during operation

  • Shortening testing time can improve throughput

  • The repeatability of the results is higher

control function
  • Fully automatic flow, temperature, and relative humidity control throughout the entire testing process

  • Development and Suggestions for Automatic Testing Methods

  • Programmable Multi Test Sorting

  • Printing and exporting the final test report for z

  • Built in sensor protection

Touch screen interface
  • Intuitive automation operations require less training

  • Built in multi-level user management and data security

  • Event logs and troubleshooting guide

  • No need to use PC, saving valuable laboratory space

COULOX®sensor
  • Short exam time can reduce overall testing time, thereby improving throughput

  • No need to calibrate sensors

  • Longer lifespan than other sensors on the market

  • Compared to sensors that require calibration, the results are more accurate and reproducible

  • The intrinsic Coulomb sensor complies with ASTM D3985

warranty
  • 12 months of 100% parts and process warranty

  • COUPOX sensor 4-year warranty

Function - Specific Model:

unit

H-shaped

A型

Test range (50 cm)2)

cc/(m2X days)

0.05 to 200

0.1 to 200

cc/(100 in2X days)

0.003 to 12.9

0.006 to 12.9




Test range (5.6 cm)2)

cc/(m2X days)

0.44 to 1770

0.88 to 1770

cc/(100 in2X days)

0.027 to 114.0

0.054 to 114.0




Scope of testing(5.0cm2 Masked) cc/(m2X days) 0.5 to 2000 1.0 to 2000

Test Scope - Packaging

Cc/(pkg × day)

0.00025 to 1.0

0.0005 to 1.0

Resolve (50 cm)2) cc/(m2X days) 0.0001 0.0001

repetitiveness

cc/(m2X days)

0.02 or 1%*

0.02 or 1%*

*Whichever is larger
Function - All models

OX-TRAN 2/22 series

unit

Test temperature range

20-40 °C +/- 0.2 °C

Controlled RH testing range, testing gas

0%, 30-90% +/- 3%

Controlled RH testing range, carrier gas

0%, 30-90% +/- 3%

Film Size

4 "x 4" Std, 2 "x2" Elective

film thickness

Up to 120 Mil

Thin film testing area

50 cm2std., Options up to 5.6 cm2

Other specifications (all models):

Physical specifications

  • 15.5” H x 12” W x 23” D (39.4 cm x 30.4 cm x 58.0 cm)

  • 95 Lbs. (43.1 kg)

Electrical requirements

  • Voltage: 100-240 VAC 50/60 Hz

  • High power consumption: 700 VA

Laboratory requirements

temperature

surgery

22 °C ± 2 °C

storage

10 ° C to 30 ° C

humidity

surgery

20% to 80% RH (non condensing)

storage

5% to 85% RH (non condensing)

Gas supply requirements

carrier gas

gas composition

Nitrogen/hydrogen mixture (98%/2%)

Nominal supply pressure

25 PSI, (1.72 Bar), (172 kPa)

Test gas

gas composition

100% oxygen (purity 99.9%)

Nominal supply pressure

25 PSI, (1.72 Bar), (172 kPa)

connectivity
  • Remote access and control (requires optional PERM-NET Lite software)

  • Standard Ethernet port (100T)

  • Dual USB 2.0 ports (for connecting keyboards, mice, or storage devices)

Compliance standards

Equipment type: Electrical equipment for measurement, control, and laboratory use

Equipment type: Penetration analyzer

Application of Council Directive:

  • 2006/42/EU Machinery Directive

  • 2014/30/EU EMC Directive

  • 2011/65/EU RoHS Directive

Declaration of compliance with standards:

  • IEC/EN 60204-1:2018

  • IEC 61010-1: 2010+A1 2019

  • EN 61326-1: 2021

  • -
  • A-class radiation and conduction


  • -
  • Basic Immune Testing Requirements

accessories

Ink cartridges and options
  • Shrink Area Ink Cartridge

  • Edge Effect Ink Cartridge

  • contact lens case

  • Customized design test box

  • Encapsulation test adapter

consumables
  • Certified Movies 1-3 and Settings

  • mask

software
  • PermWare Data Collection, Data Management, and Instrument Status Dashboard

  • 21 CFR Part 11 User and Data Security

Service and Support Options
  • Basic Preventive Maintenance Plan

  • Add preventive maintenance plan

application

packaging film
  • single layer

  • multi-layer

  • Coating film

  • Copperplate/cardboard

Compliance with testing standards

ASTM D3985
ASTM F2622
ASTM F1307
ASTM F1927
ISO CD 15105-2
JIS K-7126-2
DIN 53380-3
GB/T 19789-2005
GB/T 31354-2014

Standard Test Method for Measuring the Transmittance of Oxygen through Plastic Films and Sheets Using Coulombic Sensors

The test sample is installed as a half barrier between two chambers at ambient atmospheric pressure. One chamber is slowly purged with nitrogen gas flow, while the other chamber contains oxygen. When oxygen passes through the membrane and enters the nitrogen carrier gas, it is transported to the Coulomb detector, where an electric current is generated. The magnitude of the current is proportional to the amount of oxygen flowing into the detector per unit time.