Oxygen permeation analyzer

NegotiableUpdate on 01/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The OX-TRAN 2/22 series is a MOCON OTR analyzer used for testing materials with high barriers, OX-TRAN 2/22 series -2-cell battery oxygen permeation analyzer, film and packaging testing, nASTM D3985, n2 chamber testing chamber system
Product Details

OX-TRAN 2/22 seriesOxygen permeation analyzerOX-TRAN 2/22 series -2 batteries


The OX-TRAN 2/22 series 2-core high-performance analyzer can test the oxygen permeability (OTR) of films and packaging from low barrier to very high barrier. Used for packaging and filmOxygen permeation analyzerEasy to use and provides a short testing time in the market. They have 2 independent units with replaceable horizontal test boxes, which can easily and accurately test various sample sizes and types.

Z high accuracy

  • Obtain the exclusive COUPOX ® The sensor is an absolute Coulomb sensor on the market, which does not require calibration

  • The low detection level of any available instrument is as low as 0.0005 cc/(m2 × day) (10X model)

  • Fully automatic temperature, flow, and relative humidity control simplifies testing and provides repeatability

Z optimal throughput

  • Fast sensor response time in the industry can shorten overall testing time

  • Detachable test box enables fast and easy sample preparation

  • Automated testing methods can start testing with just one button press

  • TruSeal ® Gas flushing of the surrounding seal can eliminate the need for individual zeroing in many tests, thereby shortening the overall testing time

The 2/22 series adopts MOCON's specialized * COUPOX absolute (intrinsic) coulombic sensor, which does not require calibration and is ASTM D3985. It is an instrument series that has been independently tested and proven to meet accuracy and bias requirements by a third party.

Model:

This high-precision instrument series has three models, each with different lower detection limit factors:

  • H model (common barrier) - popular detection range from 0.05 to 200 cc/(m2 × day)

  • L model (high barrier) - capable of achieving 10 times lower performance than H model, providing a range of 0.005 to 200 cc/(m2 × day)


  • 10X model (ultra-high barrier) - has a detection level that is lower than the industry's z, 100 times lower than the H model, with a detection range of 0.0005 to 200 cc/(m2 × day).

Its detection limit is 200 cc/(m2 × day), which can be extended to normal 100% O2 (coefficient 4.8) or various sizes of masking by using a reduced area film test box (factor × 9), any model with atmospheric oxygen in place. This series has industry features such as detachable and interchangeable level test boxes, easy-to-use touchscreen operator interfaces, and fully automated testing that provides higher throughput in the laboratory.

For 25 years, MOCON's OX-TRAN series instruments have been trusted and durable in the market. From simple single-layer barriers to complex multi-layer barriers, the OX-TRAN 2/22 series is the right choice.


Advantages and characteristics

Detachable test chamber
  • Easily prepare samples on the workbench

  • One click release and loading

  • Pneumatic clamping ensures more reproducible results

  • The interchangeable test chamber box options expand the range and flexibility of the analyzer, eliminating the need for tools while maintaining accurate results

  • The test chamber box options include: a small area test chamber for expanding the testing range (without the need for a face mask) and improving the testing accuracy of paper-based barrier materials, and a test chamber for packaging orharshAdaptors for remote testing and custom designed test chambers for special requirements.

TruSeal®
  • The sample installation is sealed with nitrogen circulation to protect the integrity of the chamber

  • Reduce the background level and minimize the need for running individual zeroing

  • Shorten testing time and improve throughput

  • More reproducible results

control function
  • Throughout the entire testing process, fully automated flow, temperature, and relative humidity control

  • Development and Suggestions for Automatic Testing Methods

  • Programmable multi test sequence

  • Printing and exporting the final test report for z

  • Built in sensor protection

Touch screen interface
  • Intuitive automation operations require minimal training

  • Built in multi-level user management and data security

  • Event logs and troubleshooting guidelines

  • No need to use a computer, saving valuable laboratory space

COULOX ® Sensors
  • Shorten testing time, reduce overall testing time, and improve throughput

  • No need for sensor calibration

  • The lifespan of the sensor is longer than other sensors on the market

  • Compared to sensors that require calibration, the results are more accurate and reproducible

  • Coulombometer sensor meets ASTM D3985 standard

warranty
  • 12-month 100% parts and process warranty

  • Coulox Sensor 4-Year Warranty

Technical Specifications

Function - Specific Model

unit

Model 10x

L-shaped

H-shaped

Test range (50 cm)2)

cc/(m2X days)

0.0005 to 200

0.005 to 200

0.05 to 200

cc/(100 in2X days)

0.00003 to 12.9

0.0003 to 12.9

0.003 to 12.9





Test range (5.6 cm)2)

cc/(m2X days)

0.0044 to 1770

0.044 to 1770

0.44 to 1770

cc/(100 in2X days)

0.00027 to 114.0

0.0027 to 114.0

0.027 to 114.0





Scope of testing(5.0cm2 Masked) cc/(m2X days) 0.005 to 2000 0.05 to 2000 0.5 to 2000

Test Scope - Packaging

Cc/(pkg × day)

0.0000025 to 1.0

0.000025 to 1.0

0.00025 to 1.0

Resolve (50cm)2) cc/(m2X days) 0.0001 0.0001 0.0001

repetitiveness

cc/(m2X days)

0.0005 or 1%*

0.002 or 1%*

0.02 or 1%*


*Whichever is larger

Function - All models

OX-TRAN 2/22 series

unit

Test temperature range

10 ° to 40 ° C ± 0.2 ° C

Controlled relative humidity testing range

0 to 90% ± 3%

Film size

4-inch x 4-inch standard, 2-inch x 2-inch optional

film thickness

Up to 120 Mil

Thin film testing area

50 cm2Standard, 5.6 cm2optional

Other specifications (all models):

Physical specifications

  • 15.5 inches high x 12 inches wide x 23 inches deep (39.4 cm x 30.4 cm x 58.0 cm)

  • 95 pounds (43.1 kg)

Electrical requirements

  • Voltage: 100-240 VAC 50/60 Hz

  • High power consumption: 700 VA

Laboratory requirements

temperature

operation

22°C ± 2°C

storage

10 ° C to 30 ° C

humidity

operation

20% to 80% RH (non condensing)

storage

5% to 85% RH (non condensing)

Gas supply requirements

carrier gas

gas composition

Nitrogen/hydrogen mixture (98%/2%)

Rated gas supply pressure

25 PSI, (1.72 bar), (172 kPa)

Test gas

gas composition

100% oxygen (purity 99.9%)

Rated gas supply pressure

25 PSI, (1.72 bar), (172 kPa)

connect
  • Remote access and control (requires optional Perm Net Light software)

  • Standard Ethernet port (100T)

  • Dual USB 2.0 ports (for connecting keyboards, mice, or storage devices)

connectivity
  • Remote access and control (requires optional PERM-NET Lite software)

  • Standard Ethernet port (100T)

  • Dual USB 2.0 ports (for connecting keyboards, mice, or storage devices)

Compliance standards

Equipment type: Electrical equipment for measurement, control, and laboratory use

Equipment type: Penetration analyzer

Application of Council Directive:

  • 2006/42/EU Machinery Directive

  • 2014/30/EU EMC Directive

  • 2011/65/EU RoHS Directive

Declaration of compliance with standards:

  • IEC/EN 60204-1:2018

  • IEC 61010-1: 2010+A1 2019

  • EN 61326-1: 2021

  • -
  • A-class radiation and conduction


  • -
  • Basic Immune Testing Requirements

accessories

Test cabin and options

Small area testing cabin

Edge Effect Test Cabin

Contact lens testing cabin

Customized Design Test Cabin

Packaging Test Adapter

consumables

Certification film 1-4&set

face shield

software

PermWare Data Collection, Data Management, and Instrument Status Dashboard

21 CFR Part 11 User and Data Security

Service and Support Options

IQ/OQ files and verification

Basic Preventive Maintenance Plan

Advanced Preventive Maintenance Plan


application

packaging film

single layer

multi-layer

Coating film

Coated paper/cardboard

special film

Gel/lotion

packaging

Ordinary food packaging

Medical packaging

Bottle/Cap

sealing element

O-ring

washer

Test Standard

ASTM D3985
ASTM F2622
ASTM F1307
ASTM F1927
ISO CD 15105-2
JIS K-7126-B
DIN 53380-3
GB/T 19789-2005
GB/T 31354-2014

test method

According to ASTM D3985

Standard test method for determining the transmittance of oxygen through plastic films and sheets using a coulomb sensor

Install the test sample as a semi barrier material between two chambers under ambient atmospheric pressure. One chamber is slowly purged with nitrogen gas flow, while the other chamber contains oxygen. When oxygen permeates through the membrane into the nitrogen carrier gas, it will be transported to the coulomb detector, where a current is generated that is proportional to the amount of oxygen entering the detector per unit time.