OX-TRAN 2/22 seriesOxygen permeation analyzerOX-TRAN 2/22 series -2 batteries
The OX-TRAN 2/22 series 2-core high-performance analyzer can test the oxygen permeability (OTR) of films and packaging from low barrier to very high barrier. Used for packaging and filmOxygen permeation analyzerEasy to use and provides a short testing time in the market. They have 2 independent units with replaceable horizontal test boxes, which can easily and accurately test various sample sizes and types.
Z high accuracy
Obtain the exclusive COUPOX ® The sensor is an absolute Coulomb sensor on the market, which does not require calibration
The low detection level of any available instrument is as low as 0.0005 cc/(m2 × day) (10X model)
Fully automatic temperature, flow, and relative humidity control simplifies testing and provides repeatability
Z optimal throughput
Fast sensor response time in the industry can shorten overall testing time
Detachable test box enables fast and easy sample preparation
Automated testing methods can start testing with just one button press
TruSeal ® Gas flushing of the surrounding seal can eliminate the need for individual zeroing in many tests, thereby shortening the overall testing time
The 2/22 series adopts MOCON's specialized * COUPOX absolute (intrinsic) coulombic sensor, which does not require calibration and is ASTM D3985. It is an instrument series that has been independently tested and proven to meet accuracy and bias requirements by a third party.
This high-precision instrument series has three models, each with different lower detection limit factors:
H model (common barrier) - popular detection range from 0.05 to 200 cc/(m2 × day)
L model (high barrier) - capable of achieving 10 times lower performance than H model, providing a range of 0.005 to 200 cc/(m2 × day)
10X model (ultra-high barrier) - has a detection level that is lower than the industry's z, 100 times lower than the H model, with a detection range of 0.0005 to 200 cc/(m2 × day).
Its detection limit is 200 cc/(m2 × day), which can be extended to normal 100% O2 (coefficient 4.8) or various sizes of masking by using a reduced area film test box (factor × 9), any model with atmospheric oxygen in place. This series has industry features such as detachable and interchangeable level test boxes, easy-to-use touchscreen operator interfaces, and fully automated testing that provides higher throughput in the laboratory.
For 25 years, MOCON's OX-TRAN series instruments have been trusted and durable in the market. From simple single-layer barriers to complex multi-layer barriers, the OX-TRAN 2/22 series is the right choice.
Advantages and characteristics
Easily prepare samples on the workbench
One click release and loading
Pneumatic clamping ensures more reproducible results
The interchangeable test chamber box options expand the range and flexibility of the analyzer, eliminating the need for tools while maintaining accurate results
The test chamber box options include: a small area test chamber for expanding the testing range (without the need for a face mask) and improving the testing accuracy of paper-based barrier materials, and a test chamber for packaging orharshAdaptors for remote testing and custom designed test chambers for special requirements.
The sample installation is sealed with nitrogen circulation to protect the integrity of the chamber
Reduce the background level and minimize the need for running individual zeroing
Shorten testing time and improve throughput
More reproducible results
Throughout the entire testing process, fully automated flow, temperature, and relative humidity control
Development and Suggestions for Automatic Testing Methods
Programmable multi test sequence
Printing and exporting the final test report for z
Built in sensor protection
Intuitive automation operations require minimal training
Built in multi-level user management and data security
Event logs and troubleshooting guidelines
No need to use a computer, saving valuable laboratory space
Shorten testing time, reduce overall testing time, and improve throughput
No need for sensor calibration
The lifespan of the sensor is longer than other sensors on the market
Compared to sensors that require calibration, the results are more accurate and reproducible
Coulombometer sensor meets ASTM D3985 standard
12-month 100% parts and process warranty
Coulox Sensor 4-Year Warranty
Technical Specifications
unit |
Model 10x |
L-shaped |
H-shaped |
|
Test range (50 cm)2) |
cc/(m2X days) |
0.0005 to 200 |
0.005 to 200 |
0.05 to 200 |
cc/(100 in2X days) |
0.00003 to 12.9 |
0.0003 to 12.9 |
0.003 to 12.9 |
|
Test range (5.6 cm)2) |
cc/(m2X days) |
0.0044 to 1770 |
0.044 to 1770 |
0.44 to 1770 |
cc/(100 in2X days) |
0.00027 to 114.0 |
0.0027 to 114.0 |
0.027 to 114.0 |
|
| Scope of testing(5.0cm2 Masked) | cc/(m2X days) | 0.005 to 2000 | 0.05 to 2000 | 0.5 to 2000 |
Test Scope - Packaging |
Cc/(pkg × day) |
0.0000025 to 1.0 |
0.000025 to 1.0 |
0.00025 to 1.0 |
| Resolve (50cm)2) | cc/(m2X days) | 0.0001 | 0.0001 | 0.0001 |
repetitiveness |
cc/(m2X days) |
0.0005 or 1%* |
0.002 or 1%* |
0.02 or 1%* |
*Whichever is larger
OX-TRAN 2/22 series |
unit |
Test temperature range |
10 ° to 40 ° C ± 0.2 ° C |
Controlled relative humidity testing range |
0 to 90% ± 3% |
Film size |
4-inch x 4-inch standard, 2-inch x 2-inch optional |
film thickness |
Up to 120 Mil |
Thin film testing area |
50 cm2Standard, 5.6 cm2optional |
Physical specifications
15.5 inches high x 12 inches wide x 23 inches deep (39.4 cm x 30.4 cm x 58.0 cm)
95 pounds (43.1 kg)
Electrical requirements
Voltage: 100-240 VAC 50/60 Hz
High power consumption: 700 VA
temperature |
operation |
22°C ± 2°C |
storage |
10 ° C to 30 ° C |
|
humidity |
operation |
20% to 80% RH (non condensing) |
storage |
5% to 85% RH (non condensing) |
carrier gas |
gas composition |
Nitrogen/hydrogen mixture (98%/2%) |
Rated gas supply pressure |
25 PSI, (1.72 bar), (172 kPa) |
|
Test gas |
gas composition |
100% oxygen (purity 99.9%) |
Rated gas supply pressure |
25 PSI, (1.72 bar), (172 kPa) |
Remote access and control (requires optional Perm Net Light software)
Standard Ethernet port (100T)
Dual USB 2.0 ports (for connecting keyboards, mice, or storage devices)
Remote access and control (requires optional PERM-NET Lite software)
Standard Ethernet port (100T)
Dual USB 2.0 ports (for connecting keyboards, mice, or storage devices)
Equipment type: Electrical equipment for measurement, control, and laboratory use
Equipment type: Penetration analyzer
Application of Council Directive:
2006/42/EU Machinery Directive
2014/30/EU EMC Directive
2011/65/EU RoHS Directive
Declaration of compliance with standards:
IEC/EN 60204-1:2018
IEC 61010-1: 2010+A1 2019
EN 61326-1: 2021
A-class radiation and conduction
Basic Immune Testing Requirements
accessories
Test cabin and options
Small area testing cabin
Edge Effect Test Cabin
Contact lens testing cabin
Customized Design Test Cabin
Packaging Test Adapter
consumables
Certification film 1-4&set
face shield
software
PermWare Data Collection, Data Management, and Instrument Status Dashboard
21 CFR Part 11 User and Data Security
Service and Support Options
IQ/OQ files and verification
Basic Preventive Maintenance Plan
Advanced Preventive Maintenance Plan
application
packaging film
single layer
multi-layer
Coating film
Coated paper/cardboard
special film
Gel/lotion
packaging
Ordinary food packaging
Medical packaging
Bottle/Cap
sealing element
O-ring
washer
Test Standard
ASTM D3985
ASTM F2622
ASTM F1307
ASTM F1927
ISO CD 15105-2
JIS K-7126-B
DIN 53380-3
GB/T 19789-2005
GB/T 31354-2014
test method
According to ASTM D3985
Standard test method for determining the transmittance of oxygen through plastic films and sheets using a coulomb sensor
Install the test sample as a semi barrier material between two chambers under ambient atmospheric pressure. One chamber is slowly purged with nitrogen gas flow, while the other chamber contains oxygen. When oxygen permeates through the membrane into the nitrogen carrier gas, it will be transported to the coulomb detector, where a current is generated that is proportional to the amount of oxygen entering the detector per unit time.