X-ray fluorescence analyzer for sulfur/chlorine in oil

NegotiableUpdate on 05/10
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The MESA-7220V2 X-ray fluorescence analyzer measures sulfur and chlorine in petroleum products using monochromatic energy dispersive X-ray fluorescence (EDXRF) method. Using a monochromatic X-ray source can obtain an ultra-low noise background, providing lower detection limits for sulfur and chlorine detection.
Product Details

MESA-7220V2X-ray fluorescence analyzer for sulfur/chlorine in oil

MESA-7220V2 uses monochromatic energy dispersive X-ray fluorescence (EDXRF) method to measure sulfur and chlorine in petroleum products. Using a monochromatic X-ray source can obtain an ultra-low noise background, providing lower detection limits for sulfur and chlorine detection.

The detector window size is increased to collect more fluorescent X-rays, enabling the detection of sulfur-containing and chlorinated petroleum products at levels as low as a few ppm. The detection of sulfur and chlorine in petroleum products provides excellent and reproducible performance at both low and high concentrations.

By adjusting the angle of graphite crystals and exciting sulfur in the sample with a measurable excitation beam, sensitivity can be improved.



MESA-7220V2X-ray fluorescence analyzer for sulfur/chlorine in oilSummary

• Dynamic analysis scope

硫: 0.7 ppm - 10.0Wt%

氯: 0.6 ppm - 10.0Wt%


Automatically adjust the detection range of the extended curve.

No gas blowing is required.

Up to 60 calibration curves can be set, with a maximum of 300 points per curve.

You can edit and save the calibration curve.

The detection time ranges from 30 seconds to 999 seconds.

• Repeat measurements 1 to 99 times

The oxygen correction function eliminates its impact on sulfur readings.

• Can measure multiple sample types (solid, liquid, powder, paste, particle, and film).

You can set up 20 management and usage accounts.

• Removable Kapton window

The micrometer level adjustment of graphite crystal angle provides higher sensitivity.

A standalone PC allows software upgrades.

The built-in linkage device protects the operator from X-ray injuries.

Silicon drift detector/X-ray beryllium window.